Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Orthopaedics ; (12): 826-832, 2019.
Article in Chinese | WPRIM | ID: wpr-802580

ABSTRACT

Objective@#To investigate the incidence of complications following minimal invasive subcutaneous internal fixator (INFIX) for the treatment of anterior pelvic ring instability, and to analyze control measures.@*Methods@#Data of 42 patients with anterior pelvic ring instability who were treated by anterior subcutaneous internal fixation in our hospital from January 2016 to December 2017 were retrospectively analyzed. There were 15 females and 27 males with an average age of 45.4 years (range, 18-67 years). There were 26 traffic injuries, 10 falling injuries, 3 crush injuries and 3 low energy injuries. According to Tile classification, 24 cases of B2 type, 16 cases of B3 type, 1 case of C1 type and 1 case of C2 type. According to Young-Burgess classification, there were 20 cases of LCI, 18 cases of LCII, 1 case of LCIII, 1 case of APCI, 1 case of APCII, and 1 case of VS. Fourteen cases were combined with limb fractures, and 11 cases were combined with thoracic or abdominal injuries requiring surgical treatment, while 16 cases were with brain injuries. For type APC2, LC1, and some LC2 fractures, fixation for the anterior pelvic ring is enough with INFIX technique alone. For some LC2, LC3, or VS fractures, the anterior and posterior ring were both fixed. Postoperative reduction was evaluated by Matta radiological criteria. Lateral thigh numbness and pain, quadriceps muscle power were recorded during follow-up, and clinical efficacy was evaluated by Majeed score at 6 months after operation.@*Results@#All the 42 patients were followed up for 6 to 12 months, with an average of 9.3 months. Matta standard evaluation for fracture reduction showed that 28 cases were excellent, 14 cases good, and the excellent and good rate was 100%. The early complication rate (within 3 month after operation) was 23.8% (10/42) including 6 cases of lateral femoral cutaneous nerve injury and 2 cases of femoral nerve injury. The symptoms were obviously relieved after the treatment of nutrient nerve and hyperbaric oxygen; 1 case had incision infection which was healed after anti-infection therapy and internal plant removal; 1 case suffered from superior gluteal artery injury which was controlled by pressure hemostasis. Six months after surgery, no case had lost reduction. At 6 months follow-up, the Majeed score was 72-96, with an average of 84.96, of which 32 were excellent and 10 were good, thus the excellent and good rate was 100% (42/42).@*Conclusion@#INFIX is an effective internal fixation method for the treatment of unstable anterior pelvic ring injury. However, it has a high rate of early complications, among which nerve injury has the highest incidence.

2.
Chinese Journal of Orthopaedics ; (12): 817-825, 2019.
Article in Chinese | WPRIM | ID: wpr-802579

ABSTRACT

Objective@#To investigate the feasibility and short term clinical efficacy of early minimally invasive treatment of complex pelvic trauma with Starr reduction frame combined with O-arm navigation system.@*Methods@#From June 2017 to December 2018, thirty two patients with Tile C complex pelvic fractures were prospectively divided into two groups according to the random number table. The open treatment group included 17 cases (open reduction and internal fixation group; 10 males and 7 females, age 24-60 years, average 37±6.5 years; according to Tile classification, 8 cases of C1 type, 8 cases of C2 type and 1 case of C3 type; according to the Denis classification of sacral fractures, 9 cases in zone I, 6 cases in zone II and 2 cases in zone III). The combined treatment group included 15 cases (Starr reduction frame group combined with O-arm navigation system, 8 males and 7 females, age 32-57 years, average 40±5.2 years; according to Tile classification, 8 cases of C1 type, 6 cases of C2 type and 1 case of C3 type; according to the Denis classification of sacral fractures, 8 cases in zone I, 5 cases in zone II and 2 cases in zone III). The ilioinguinal and Stoppa approaches were used in the open treatment group, and the anterior and posterior ring injuries were fixed with reconstruction plate screws and hollow screws, respectively. In the combined treatment group, starr frame was used to assist reduction, combined with "O" arm navigation technique, infix internal fixation frame, superior pubic branch screw, sacroilium screw were used to fix the anterior and posterior ring injury. The quality of pelvic fracture reduction was evaluated by the Matta scoring system, and the Majeed score was used to evaluate the clinical efficacy.@*Results@#All patients were followed up for 6 to 12 months. The hospitalization time (45±11 d), operation time (220.0±49.4 min) and fracture healing time (24.0±5.6 weeks) in the open treatment group were longer than those in the combined treatment group (21±9 d, 180.0±24.2 min, 16.1±3.8 weeks), and the intraoperative blood loss (820.0±140.4 ml) was significantly higher than that in the combined treatment group (24.0±10.4 ml)(t=6.651, 2.772, 6.128, 22.874; all P< 0.05). According to Matta scoring system, in the open treatment group, there are 8 excellent cases, 6 good cases, 2 fair cases, 1 poor case, thus the excellent and good rate was 82.4%(14/17). While 9 cases were excellent, 5 good, 1 fair, and the excellent and good rate was 93.3% (14/15) in the combined treatment group. At the latest follow-up, Majeed score was 51-85 points in the open treatment group, including excellent in 8 cases, good in 6 cases, fair in 2 cases, poor in 1 case, thus the excellent and good rate 82.4% (14/17), and the Majeed score was 75-95 points in the combined treatment group, including excellent in 9 cases, good in 5 cases, fair in 1 case, thus excellent and good rate 93.3% (14/15). There was a statistically significant difference between the two groups of Matta score and Majeed score (χ2=0.034, 0.040; P< 0.05). Surgical infection occurred in 4 cases in the open treatment group and healed after debridement and treatment with sensitive antibiotics. The incidence of complications was 23.5% (4/17). In the combined treatment group, 2 cases had anterolateral thigh skin sensory loss after operation, and the symptoms were relieved after mannitol, mecobalamine treatment and removal of internal fixations. One patient had hematoma of the gluteus maximus muscle after operation. The result of angiography showed that the INFIX screw was too long and perforated near the foramen of the ischium, resulting from the injury of the superior gluteal artery. After stopping the use of anticoagulant, intravenous infusion of tranexamic acid, blood transfusion, etc., the patient was cured and discharged from hospital. The incidence of complications was 20.0% (3/15). There was no significant difference in the incidence of complications between the two groups.@*Conclusion@#With the help of starr reduction frame, the early reduction and minimally invasive treatment of pelvic fracture can be realized, and the amount of intraoperative bleeding can be reduced. The combined application of "o" arm navigation can improve the accuracy and safety of sacroiliac screw and anterior column screw placement, reduce the radiation dose and frequency of operators and patients, shorten the operation time and improve the curative effect.

3.
Chinese Journal of Orthopaedics ; (12): 826-832, 2019.
Article in Chinese | WPRIM | ID: wpr-755224

ABSTRACT

Objective To investigate the incidence of complications following minimal invasive subcutaneous internal fixator (INFIX) for the treatment of anterior pelvic ring instability, and to analyze control measures. Methods Data of 42 patients with anterior pelvic ring instability who were treated by anterior subcutaneous internal fixation in our hospital from January 2016 to December 2017 were retrospectively analyzed. There were 15 females and 27 males with an average age of 45.4 years (range, 18-67 years). There were 26 traffic injuries, 10 falling injuries, 3 crush injuries and 3 low energy injuries. According to Tile classi?fication, 24 cases of B2 type, 16 cases of B3 type, 1 case of C1 type and 1 case of C2 type. According to Young?Burgess classifica?tion, there were 20 cases of LCI, 18 cases of LCII, 1 case of LCIII, 1 case of APCI, 1 case of APCII, and 1 case of VS. Fourteen cas?es were combined with limb fractures, and 11 cases were combined with thoracic or abdominal injuries requiring surgical treat?ment, while 16 cases were with brain injuries. For type APC2, LC1, and some LC2 fractures, fixation for the anterior pelvic ring is enough with INFIX technique alone. For some LC2, LC3, or VS fractures, the anterior and posterior ring were both fixed. Postoper?ative reduction was evaluated by Matta radiological criteria. Lateral thigh numbness and pain, quadriceps muscle power were re? corded during follow?up, and clinical efficacy was evaluated by Majeed score at 6 months after operation. Results All the 42 pa?tients were followed up for 6 to 12 months, with an average of 9.3 months. Matta standard evaluation for fracture reduction showed that 28 cases were excellent, 14 cases good, and the excellent and good rate was 100% . The early complication rate (within 3 month after operation) was 23.8% (10/42) including 6 cases of lateral femoral cutaneous nerve injury and 2 cases of femoral nerve injury. The symptoms were obviously relieved after the treatment of nutrient nerve and hyperbaric oxygen; 1 case had incision in?fection which was healed after anti?infection therapy and internal plant removal; 1 case suffered from superior gluteal artery injury which was controlled by pressure hemostasis. Six months after surgery, no case had lost reduction. At 6 months follow?up, the Ma?jeed score was 72-96, with an average of 84.96, of which 32 were excellent and 10 were good, thus the excellent and good rate was 100% (42/42). Conclusion INFIX is an effective internal fixation method for the treatment of unstable anterior pelvic ring inju?ry. However, it has a high rate of early complications, among which nerve injury has the highest incidence.

4.
Chinese Journal of Orthopaedics ; (12): 817-825, 2019.
Article in Chinese | WPRIM | ID: wpr-755223

ABSTRACT

Objective To investigate the feasibility and short term clinical efficacy of early minimally invasive treatment of complex pelvic trauma with Starr reduction frame combined with O?arm navigation system. Methods From June 2017 to De?cember 2018, thirty two patients with Tile C complex pelvic fractures were prospectively divided into two groups according to the random number table. The open treatment group included 17 cases (open reduction and internal fixation group; 10 males and 7 fe?males, age 24-60 years, average 37±6.5 years;according to Tile classification, 8 cases of C1 type, 8 cases of C2 type and 1 case of C3 type; according to the Denis classification of sacral fractures, 9 cases in zone I, 6 cases in zone II and 2 cases in zone III). The combined treatment group included 15 cases (Starr reduction frame group combined with O?arm navigation system, 8 males and 7 females, age 32-57 years, average 40±5.2 years; according to Tile classification, 8 cases of C1 type, 6 cases of C2 type and 1 case of C3 type; according to the Denis classification of sacral fractures, 8 cases in zone I, 5 cases in zone II and 2 cases in zone III). The ilioinguinal and Stoppa approaches were used in the open treatment group, and the anterior and posterior ring injuries were fixed with reconstruction plate screws and hollow screws, respectively. In the combined treatment group, starr frame was used to assist reduction, combined with "O" arm navigation technique, infix internal fixation frame, superior pubic branch screw, sacro?ilium screw were used to fix the anterior and posterior ring injury. The quality of pelvic fracture reduction was evaluated by the Matta scoring system, and the Majeed score was used to evaluate the clinical efficacy. Results All patients were followed up for 6 to 12 months. The hospitalization time (45±11 d), operation time (220.0±49.4 min) and fracture healing time (24.0±5.6 weeks) in the open treatment group were longer than those in the combined treatment group (21±9 d, 180.0±24.2 min, 16.1±3.8 weeks), and the intraoperative blood loss (820.0±140.4 ml) was significantly higher than that in the combined treatment group (24.0±10.4 ml) (t=6.651, 2.772, 6.128, 22.874; all P<0.05). According to Matta scoring system, in the open treatment group, there are 8 excellent cases, 6 good cases, 2 fair cases, 1 poor case, thus the excellent and good rate was 82.4%(14/17). While 9 cases were excellent, 5 good, 1 fair, and the excellent and good rate was 93.3% (14/15) in the combined treatment group. At the latest follow?up, Majeed score was 51-85 points in the open treatment group, including excellent in 8 cases, good in 6 cases, fair in 2 cases, poor in 1 case, thus the excellent and good rate 82.4% (14/17), and the Majeed score was 75-95 points in the combined treatment group, includ?ing excellent in 9 cases, good in 5 cases, fair in 1 case, thus excellent and good rate 93.3% (14/15). There was a statistically signifi?cant difference between the two groups of Matta score and Majeed score (χ2=0.034, 0.040; P<0.05). Surgical infection occurred in 4 cases in the open treatment group and healed after debridement and treatment with sensitive antibiotics. The incidence of compli?cations was 23.5% (4/17). In the combined treatment group, 2 cases had anterolateral thigh skin sensory loss after operation, and the symptoms were relieved after mannitol, mecobalamine treatment and removal of internal fixations. One patient had hematoma of the gluteus maximus muscle after operation. The result of angiography showed that the INFIX screw was too long and perforated near the foramen of the ischium, resulting from the injury of the superior gluteal artery. After stopping the use of anticoagulant, in?travenous infusion of tranexamic acid, blood transfusion, etc., the patient was cured and discharged from hospital. The incidence of complications was 20.0% (3/15). There was no significant difference in the incidence of complications between the two groups. Conclusion With the help of starr reduction frame, the early reduction and minimally invasive treatment of pelvic fracture can be realized, and the amount of intraoperative bleeding can be reduced. The combined application of "o" arm navigation can im?prove the accuracy and safety of sacroiliac screw and anterior column screw placement, reduce the radiation dose and frequency of operators and patients, shorten the operation time and improve the curative effect.

SELECTION OF CITATIONS
SEARCH DETAIL